EchoNet-Dynamic: video-based AI for left ventricular ejection fraction
A deep learning model trained on echocardiogram videos segmented the left ventricle with a Dice coefficient of 0.92 and estimated ejection fraction with a mean absolute error of 4.1% (6.0% on an external dataset from another health system). Prospective evaluation with repeated human measurements found its variance comparable to or lower than that of human experts. Caveat: training data come from one institution's echocardiograms, with external testing on a single additional system.
Technology: EchoNet-Dynamic (video deep learning model)
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
Result, AI contribution and limits
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
- Publication status: Peer-reviewed paper
- Test type: retrospective or benchmark
- Tested: Segmentation and ejection fraction were tested on held-out internal data (Dice 0.92, MAE 4.1%) and an external dataset from another health system (MAE 6.0%), and repeated human measurements were compared with model variance.
- Still unknown: Not reported; the page states no limitations section.
- AI role: Deep learning model trained on echocardiogram videos to segment the left ventricle and estimate ejection fraction.
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:10.1038/s41586-020-2145-8&resultType=core&format=json
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: linked separately.
Review scope and date are not recorded; source checked does not establish full-text review.
Citations: in the top 1% of works of the same type, year and subfield (OpenAlex work metrics, 1292 citations; as of 15 Nov 2026). Attention, not a measure of correctness; not part of the score.
Editorial assessment: Impact 4/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.
Follow-up and relationships
No follow-up recorded; this is not a claim that no follow-up exists.
Follow-up review scope and date are not recorded.
No source-supported relationships recorded.