AI Science Tracker
EN

Estimation and Tracking of Blood Pressure Using Routinely Acquired Photoplethysmographic Signals and Deep Neural Networks

Signal and Image Processing Laboratory (SIPL), Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion - Israel Institute of Technology, Haifa, Israel · 29 Apr 2020 · medicine

Discovery

Estimation and Tracking of Blood Pressure Using Routinely Acquired Photoplethysmographic Signals and Deep Neural Networks

Source check: Source checked. Not independent scientific confirmation.

Finding: A Siamese deep network estimated blood-pressure changes from PPG after one calibration reading, using 329 MIMIC-II patients and patient-disjoint held-out evaluation. This is retrospective ICU-waveform feasibility evidence, not prospective care validation.

Technology: A Siamese deep neural network estimates blood-pressure changes from PPG using one calibration reading.

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
A Siamese deep neural network estimates blood-pressure changes from PPG using one calibration reading.
Test and result
Siamese deep network estimates blood-pressure changes from PPG relative to one calibration reading; 329 MIMIC-II patients and patient-disjoint held-out split. Retrospective ICU waveform feasibility, not prospective care validation.
Limitation / still unknown
Retrospective MIMIC-II data and a held-out split do not establish prospective bedside performance or patient benefit.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://pmc.ncbi.nlm.nih.gov/articles/PMC7188414/ · https://doi.org/10.1097/cce.0000000000000095 · https://europepmc.org/article/MED/32426737 · https://pubmed.ncbi.nlm.nih.gov/32426737/

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: linked separately.

Review date: 22 Nov 2026. Review scope: Primary result-bearing material for the stated method, result and evaluation, with bibliographic version information..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries.