PENet detects pulmonary embolism on volumetric CT angiography

Stanford University · 24 Apr 2020 · medicine

Discovery

PENet detects pulmonary embolism on volumetric CT angiography

PENet, a 3D deep-learning model for pulmonary embolism on CT angiography, reached AUROC 0.84 on an internal hold-out test and 0.85 on data from one unnamed external institution. The abstract does not report sensitivity, specificity or study size, and the external validation is limited to a single site.

Technology: PENet, 3D deep convolutional network on volumetric CT

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

Result, AI contribution and limits

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

  • Publication status: Peer-reviewed paper
  • Test type: retrospective or benchmark
  • Tested: PENet, a 3D CNN, was tested on a hold-out set from the training institution (AUROC 0.84) and on an external institution (AUROC 0.85), and was compared with other state-of-the-art 3D CNN models.
  • Still unknown: The abstract states no limitations; external validation covers one institution and sensitivity, specificity and study size are not reported.
  • AI role: A 77-layer 3D CNN, pretrained on Kinetics-600, detected pulmonary embolism on CT angiography and is proposed as a triage tool.

Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:10.1038/s41746-020-0266-y&resultType=core&format=json

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: linked separately.

Review scope and date are not recorded; source checked does not establish full-text review.

Citations: in the top 10% of works of the same type, year and subfield (OpenAlex work metrics, 203 citations; as of 15 Nov 2026). Attention, not a measure of correctness; not part of the score.

Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.