AI Science Tracker
EN

Computer-aided detection lowers adenoma miss rate in tandem colonoscopy

Sichuan Provincial People’s Hospital · 17 Jun 2020 · medicine

How tested is it?

Independently or prospectively checked

The level reflects the test the original source reports. This site does not rerun it, and it does not say whether the result is correct.

Discovery

Computer-aided detection lowers adenoma miss rate in tandem colonoscopy

Source check: Source checked. Not independent scientific confirmation.

Finding: In a prospective tandem study at one Chinese centre, 369 patients were randomly assigned to computer-aided detection (CADe) colonoscopy first or routine white-light colonoscopy first, each followed by the other procedure. The adenoma miss rate was 13.89% with CADe versus 40.00% with routine colonoscopy. The study is single-centre.

Technology: Deep learning computer-aided detection (CADe) for real-time colonoscopy

Publication: Peer-reviewed paper · Test context: prospective or independent check. Catalog categories, not an evidence grade.

AI contribution
Deep learning system alerting endoscopists to polyps in real time.
Test and result
Adenoma miss rate of CADe versus routine colonoscopy in a randomized prospective tandem design (n = 369).
Limitation / still unknown
Single centre; adenoma miss rate is not a long-term clinical outcome; full text not reviewed.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1053/j.gastro.2020.06.023%22&resultType=core&format=json

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI; affiliations from Europe PMC or Crossref where stated. Publisher full text not accessed.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 4/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries. Browse 2020 discoveries.

Related catalog entries

Links use documented relationships where available, plus shared catalog context. A shared topic or model family does not establish a scientific dependency.