Early cardiac MRI images identify pleural effusions in retrospective testing
Source check: Source checked. Not independent scientific confirmation.
Finding: An adapted HRNet segmented early anatomical cardiac MRI images and quantified pleural fluid. In a 200-scan test set containing 42 report-positive effusions, fluid quantification distinguished report-positive scans with an AUC of 0.906. Adaptive scanning and patient benefits were proposed rather than tested.
Technology: HRNet convolutional neural network
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- An adapted HRNet learned pixel labels from clinician annotations; segmented slices were reconstructed into a 3D fluid volume used to distinguish report-positive pleural effusions.
- Test and result
- Retrospective 575-scan study across two hospitals and two scanner manufacturers: 375 scans for training/validation and 200 for testing. Clinicians labelled 1,500 development slices. HRNet segmentation and 3D fluid quantification yielded pleural-effusion AUC 0.906 against final clinical reports; 42 of 200 test scans had reported effusions.
- Limitation / still unknown
- Report-based reference rather than an independently adjudicated effusion standard; no prospective workflow or patient-benefit test. Generalization beyond these centers remains uncertain. Separate chamber-size claims require manufacturer-specific regression calibration whose fitting partition is unclear, and are not represented here. Threshold-specific accuracy is omitted because optimal cut-offs were evaluated in the study dataset.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://pmc.ncbi.nlm.nih.gov/articles/PMC7969571/
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 21 Nov 2026. Review scope: Read primary full-text cohort, HRNet training, reconstruction/calibration and statistical Methods, pleural-effusion Results and limitations. Author cardiac-MRI page checked; it provides a high-level description, not additional calibration documentation. Supplementary ROC figure not independently inspected. Exact primary identity/date and fresh primary PubMed correction/retraction relationships checked..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.