Gradient boosting model predicts acute kidney injury after liver transplantation
Source check: Source checked. Not independent scientific confirmation.
Finding: Five classifiers were compared on 780 included liver transplant cases (430 with AKI, 55.1%) from 894 collected; gradient boosting performed best, with an AUC of 0.76 (CI 0.70-0.82) internally and 0.75 (CI 0.67-0.81) in an independent set of 195 later cases. SHAP identified high preoperative indirect bilirubin, low urine output, long anesthesia time, low platelets and graft steatosis as top predictors. Validation is temporal at one center and discrimination is modest.
Technology: Gradient boosting machine with SHAP explanation
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Predicts post-transplant AKI and ranks the contributing variables.
- Test and result
- Internal validation and an independent temporal dataset of 195 cases (October 2019 to March 2021).
- Limitation / still unknown
- Multi-center performance and clinical impact; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1186/s12967-021-02990-4%22&resultType=core&format=json
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract and author affiliations read from Europe PMC metadata for this DOI. Publisher full text not accessed.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.