Finding: A retrospective two-center study of 350 patients with coronary CT angiography (training 134, validation 66, testing 150 with invasive angiography) extracted 1,691 radiomic features from pericoronary tissue. Boruta with random forest selected the top 8 features to form a Rad-signature for CT-FFR of 0.8 or less, with AUCs 0.83, 0.82 and 0.82 (training, validation, testing) versus 0.55, 0.55 and 0.52 for fat attenuation index; the combined model reached 0.86, 0.85 and 0.83. Another 45 patients with invasive FFR were included to check performance. The reference for training was CT-FFR rather than invasive FFR.
Technology: Boruta feature selection with random forest on pericoronary radiomic features
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Builds the radiomics signature for functional ischemia
- Test and result
- Independent testing group (n=150) and 45 further patients with invasive FFR.
- Limitation / still unknown
- Clinical benefit of the signature; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.3389/fphys.2022.980996%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.3389/fphys.2022.980996
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Publisher full text not accessed; affiliations not looked up. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.