Accuracy of Artificial Intelligence-Based Automated Quantitative Coronary Angiography Compared to Intravascular Ultrasound: Retrospective Cohort Study.
Source check: Source checked. Not independent scientific confirmation.
Finding / tested result: In 47 patients with 54 significant coronary lesions, AI-QCA measurements showed moderate-to-strong correlation with IVUS for proximal reference area (r=0.57), distal reference area (r=0.80) and minimal luminal area (r=0.52); correlation was weaker for percent area stenosis (r=0.29) and lesion length (r=0.33). Correcting proximal/distal margin mismatch strengthened reference-area correlations to r=0.70 and r=0.83, respectively.
Technology: Fully automated artificial-intelligence quantitative coronary angiography (AI-QCA) measured coronary lesion dimensions for comparison with IVUS; adjusting lesion margins reduced geographic mismatch.
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Automated image analysis measured reference vessel areas, minimal luminal area, percent area stenosis and lesion length from coronary angiograms.
- Limitation / still unknown
- Retrospective single-center comparison in 47 patients and 54 lesions; AI-QCA correlated less well for percent stenosis and lesion length and showed geographic-margin mismatch, especially distally.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://doi.org/10.2196/45299 · https://europepmc.org/article/MED/37099368 · https://europepmc.org/articles/PMC10173041 · https://www.ncbi.nlm.nih.gov/research/bionlp/RESTful/pmcoa.cgi/BioC_json/PMC10173041/unicode
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 22 Nov 2026. Review scope: Primary result-bearing material for the stated method, result and evaluation, with bibliographic version information..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.