AI Science Tracker
EN

Trans-CNN predicts stroke recurrence from vessel wall MRI

First Affiliated Hospital of Xinxiang Medical University · 28 Mar 2025 · medicine

How tested is it?

Checked on existing data

The level reflects the test the original source reports. This site does not rerun it, and it does not say whether the result is correct.

Discovery

Trans-CNN predicts stroke recurrence from vessel wall MRI

Source check: Source checked. Not independent scientific confirmation.

Finding: ResNet50 and DenseNet169 feature extractors with Transformer attention (Trans-CNN) on culprit plaque images from 363 patients reached test AUC 0.912 (95% CI 0.839-0.969), accuracy 0.858 and sensitivity 0.880 in an external center of 109 patients. Training AUC was 0.951 in 254 patients. The test set had only 25 recurrences and the study is retrospective.

Technology: ResNet50 and DenseNet169 CNNs with Transformer attention ensemble (Trans-CNN) on HR-VWI

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
Predicts stroke recurrence from plaque imaging
Test and result
Independent external test set from a second center.
Limitation / still unknown
Prospective validation and clinical utility.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.21037/qims-24-1723%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.21037/qims-24-1723

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 26 Nov 2026. Review scope: Abstract and Europe PMC full-text Methods/Results excerpts read. Publisher version not otherwise accessed. Author affiliations from OpenAlex metadata.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries. Browse 2025 discoveries.

Related catalog entries

Links use documented relationships where available, plus shared catalog context. A shared topic or model family does not establish a scientific dependency.