Machine learning predicts acute kidney injury after off-pump coronary bypass surgery
Source check: Source checked. Not independent scientific confirmation.
Finding: On 938 off-pump bypass patients (210 with acute kidney injury, 22.39%), XGBoost on baseline and Tsfresh-extracted intraoperative time-series features was the best of the models tried. In external validation of 631 patients it reached AUC 0.982, accuracy 0.916 and precision 0.983; SHAP ranked cystatin C first and NT-proBNP second. The study is retrospective and the very high external AUC calls for prospective confirmation.
Technology: XGBoost with Tsfresh time-series feature extraction and SHAP ranking
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Predicts postoperative acute kidney injury risk
- Test and result
- Retrospective development at one hospital and external validation in 631 patients (85 with injury) at a second hospital.
- Limitation / still unknown
- Prospective validation and effect on patient outcomes; prediction only.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1016/j.jatmed.2026.06.005%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1016/j.jatmed.2026.06.005
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract and Europe PMC full-text Methods/Results excerpts read. Publisher version not otherwise accessed. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.