AI Science Tracker
EN

Machine learning outperforms Padua and IMPROVE scores for hospital-acquired VTE

Department of Hematology, Peking Union Medical College Hospital, Beijing, China · 28 Aug 2026 · medicine

How tested is it?

Checked on existing data

The level reflects the test the original source reports. This site does not rerun it, and it does not say whether the result is correct.

Discovery

Machine learning outperforms Padua and IMPROVE scores for hospital-acquired VTE

Source check: Source checked. Not independent scientific confirmation.

Finding: On 379,720 MIMIC-IV admissions (674 with imaging-confirmed VTE) out-of-fold AUCs were 0.79 to 0.81, against 0.707 for Padua and 0.688 for IMPROVE. Frozen models in 29,144 Beijing admissions did better than both scores, with the admission-safe model at AUC 0.706 versus 0.678. Discrimination is modest, and the authors call for recalibration and prospective validation; this is a retrospective preprint.

Technology: XGBoost and logistic regression models on EHR data

Publication: Preprint · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
Machine-learning models predicted imaging-confirmed in-hospital VTE.
Test and result
External validation of frozen models in a separate tertiary hospital in Beijing.
Limitation / still unknown
Prospective performance and effect on prophylaxis decisions; full text not reviewed.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://api.crossref.org/works/10.64898/2026.08.25.26361123

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 26 Nov 2026. Review scope: Abstract read from the review input and author affiliations from Crossref metadata for this DOI. Publisher full text not accessed.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries. Browse 2026 discoveries.

Related catalog entries

Links use documented relationships where available, plus shared catalog context. A shared topic or model family does not establish a scientific dependency.