Single-view echocardiography-based deep learning for pulmonary hypertension detection: a multi-level supervised and explainable approach.

Department of Ultrasound, Beijing Chaoyang Hospital Affiliated to Capital Medical University, Beijing, China;; School of Mechatronics Engineering, Beijing Institute of Technology, Beijing, China · 30 Aug 2026 · medicine

Discovery

Single-view echocardiography-based deep learning for pulmonary hypertension detection: a multi-level supervised and explainable approach.

Source check: Source checked. Not independent scientific confirmation.

Finding: A single-view echocardiography deep-learning system detected pulmonary hypertension using multi-level supervision and explainability in the reported clinical cohorts.

Technology: The learned image model used single-view echocardiography with multi-level supervision and explainability to classify pulmonary hypertension

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
The learned image model used single-view echocardiography with multi-level supervision and explainability to classify pulmonary hypertension.
Test and result
A single-view echocardiography deep-learning system detected pulmonary hypertension using multi-level supervision and explainability in the reported clinical cohorts. Evaluation: Cohort testing, comparator analyses and reported explainability checks provide bounded diagnostic validation; no deployment or outcome benefit is claimed.
Limitation / still unknown
The result is limited to the reported clinical cohorts and reference standard; prospective deployment or patient-outcome benefit is not established.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://pmc.ncbi.nlm.nih.gov/articles/PMC13654119/

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 22 Nov 2026. Review scope: Primary result-bearing material for the stated method, result and evaluation, with bibliographic version information..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries.