Clinical validation of the Swaasa® artificial intelligence platform using cough sounds for screening and aid in diagnosis of respiratory diseases.

Christian Medical College · 28 Oct 2026 · medicine

Discovery

Clinical validation of the Swaasa® artificial intelligence platform using cough sounds for screening and aid in diagnosis of respiratory diseases.

Source check: Source checked. Not independent scientific confirmation.

Finding: The cough-based AI platform screened respiratory conditions with reported clinical-validation accuracy.

Technology: Swaasa® cough-audio AI platform

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
Processes cough recordings to classify respiratory risk, spirometric pattern and severity, and disease categories against spirometry and clinician diagnoses.
Test and result
The prospective monocentric study compared cough-audio classifications with spirometry and physician-established diagnoses. It reported 90% accuracy for normal/abnormal classification and 79–84% accuracy for spirometric patterns, 76–84.5% for severity, and 83–93% for disease categories; recordings repeated within participants were not independent patients.
Limitation / still unknown
This was a monocentric exploratory diagnostic study; it does not establish improved patient outcomes or performance across other care settings.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://pmc.ncbi.nlm.nih.gov/articles/PMC13751465/

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 22 Nov 2026. Review scope: Primary result-bearing material for the stated method, result and evaluation, with bibliographic version information..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries.