A stenosis detector was tested on an external coronary angiography cohort

University of Oxford; Oxford University Hospitals NHS Trust · 23 Oct 2026 · medicine

Discovery

A stenosis detector was tested on an external coronary angiography cohort

Source check: Source checked. Not independent scientific confirmation.

Finding: A learned detector using coronary-vessel features achieved AP@50 of 0.434 on 48 angiography images from 27 Oxford Acute Myocardial Infarction study patients. Test-time augmentation raised it to 0.480. Standard YOLOv11-L scored 0.339 without augmentation. These are lesion-localization scores from a small retrospective cohort.

Technology: Fusion-YOLOv11-L; UNet++; learned vessel segmentation and lesion detection

Publication: Preprint · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
Fusion-YOLOv11-L combined learned coronary-vessel segmentation features and lesion detection features to localize stenoses in angiography frames.
Test and result
The study trained and tuned the model on ARCADE-derived data and assessed localization of 85 stenoses on separately sourced OxAMI frames.
Limitation / still unknown
The result covers selected end-diastolic frames and a small external sample. Patient-level diagnostic performance and clinical outcomes were outside this evaluation.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://arxiv.org/abs/2610.32730v1 · https://arxiv.org/html/2610.32730v1

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: linked separately.

Review date: 21 Nov 2026. Review scope: arXiv v1 date, Methods §2.1–2.4 and external test results, especially Table 5.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.