AI Science Tracker
EN

Ultrasonic texture features for assessing abnormal interventricular septum motion following cardiac surgery

Not stated in the reviewed journal article · 19 Oct 2026 · medicine

Discovery

Ultrasonic texture features for assessing abnormal interventricular septum motion following cardiac surgery

Source check: Source checked. Not independent scientific confirmation.

Finding: Ultrasound texture features differed with abnormal postoperative septal motion, and an SVM classifier distinguished the groups in a retrospective two-center study. External-center AUC was 0.803, below internal performance; the result supports a diagnostic association, not improved clinical outcomes.

Technology: LASSO feature selection and logistic-regression, random-forest, and SVM classifiers analyze ultrasound texture and shape features.

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
Learned classification of echocardiographic features enabled an evaluated association with postoperative septal motion.
Test and result
Among 650 patients, texture differences were associated with abnormal septal motion; SVM AUC was 0.943 in training, 0.948 internally, and 0.803 in an external-center cohort.
Limitation / still unknown
Retrospective diagnostic study; external performance was lower, and prospective clinical benefit was not tested. Online date 2026-10-19 precedes the 2026-11-01 issue date.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://qims.amegroups.org/article/view/161772

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 22 Nov 2026. Review scope: Primary source full-text Methods and Results; version date and reported validation scope checked..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries.