Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models
Source check: Source checked. Not independent scientific confirmation.
Finding: On 6,048 balanced ChestX-ray14 cases, HuatuoGPT-Vision and Qwen2.5-VL detected none of 432 pneumothorax-positive cases; comparison models detected 38% and 67%. This model-specific failure also appeared at larger model scale. The failure replicated on an independent SIIM-ACR set with radiologist-drawn masks: the same models detected 0/432 confirmed pneumothoraces, including 0/144 largest lesions. Retrospective diagnostic evaluation only; no clinical benefit established.
Technology: Medical vision-language models directly answered per-finding questions from chest radiographs; the study evaluated their diagnosis-specific recall, confidence and internal representations.
Publication: Preprint · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Medical vision-language models directly answered per-finding questions from chest radiographs; the study evaluated their diagnosis-specific recall, confidence and internal representations.
- Test and result
- On 6,048 balanced ChestX-ray14 cases, HuatuoGPT-Vision and Qwen2.5-VL detected none of 432 pneumothorax-positive cases; comparison models detected 38% and 67%. This model-specific failure also appeared at larger model scale.
- Limitation / still unknown
- The failure replicated on an independent SIIM-ACR set with radiologist-drawn masks: the same models detected 0/432 confirmed pneumothoraces, including 0/144 largest lesions. Retrospective diagnostic evaluation only; no clinical benefit established.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://arxiv.org/html/2611.14975v1
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 22 Nov 2026. Review scope: Read the primary preprint Methods and Results; its v1 record dates the result to 11 November 2026. The study directly evaluates medical VLMs on a specific diagnostic question: two models missed every pneumothorax in a balanced ChestX-ray14 audit while other models detected a substantial share; the failure replicated on an independent SIIM-ACR set with radiologist masks. Exact title/result comparison found no matching entry in either supplied catalog. This is retrospective diagnostic validation, not evidence of clinical benefit; ChestX-ray14 labels and binary prompts limit interpretation..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.