Deep learning on lung-screening CT estimates spirometry in two external cohorts
Source check: Source checked. Not independent scientific confirmation.
Finding: A three-dimensional convolutional neural network trained on 10,371 low-dose CT reconstructions from 5,975 NLST participants was fused with 20 densitometry and tracheal geometry features to predict FEV1, FVC and FEV1/FVC. Applied frozen to an external screening cohort (n = 268) and COPDGene (10,302 scans), it detected abnormal spirometry with AUROC 0.898 and 0.913, and concordance correlation coefficients were 0.80-0.88. Agreement was lower with overestimation in a COPD subgroup, the reference spirometry differed (pre- versus post-bronchodilator), and prospective utility is unproven.
Technology: 3D convolutional neural network fused with CT-derived densitometry and tracheal features, predicting FEV1, FVC and FEV1/FVC
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- A 3D CNN plus quantitative CT features estimated spirometric parameters from existing chest CT.
- Test and result
- A frozen model was evaluated on two external cohorts (n = 268 and 10,302 scans) against reference spirometry.
- Limitation / still unknown
- Prospective clinical utility; performance across populations, since sensitivity and specificity differed at the same decision rule; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1016/j.chest.2026.11.021%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1016/j.chest.2026.11.021
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Publisher full text not accessed; author affiliations not retrieved. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.