A finger-cuff waveform CNN screens for aortic stenosis in a multicenter cohort

Cleveland Clinic Foundation; University of Texas Southwestern Medical Center; Edwards Lifesciences; Hospital Reina Sofia de Cordoba; Amsterdam UMC, University of Amsterdam · 20 Nov 2026 · medicine

Discovery

A finger-cuff waveform CNN screens for aortic stenosis in a multicenter cohort

Source check: Source checked. Not independent scientific confirmation.

Finding: A one-dimensional convolutional model learned to identify at least moderate aortic stenosis from noninvasive finger-cuff arterial pressure waveforms, using echocardiography as reference. Development included 3,634 participants and evaluation used a temporally distinct multicenter cohort of 1,336 participants. In that cohort, significant stenosis screening had AUC 0.893, sensitivity 92.5%, specificity 64.5% and positive predictive value 36.4%. These are cohort diagnostic results, not evidence of improved patient outcomes. Prospective participant recruitment alone does not establish a frozen-model prospective evaluation; model-selection timing and full Methods were not assessed in the abstract review.

Technology: One-dimensional convolutional neural network for arterial pressure waveforms

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
A 1D convolutional network maps pressure waveforms to significant-stenosis classification; echocardiography supplied the diagnostic reference.
Test and result
Development cohort: 3,634 participants, 307 with significant stenosis; validation cohort: 1,336 participants, 241 with significant stenosis. Echo-referenced validation AUC 0.893, sensitivity 92.5%, specificity 64.5%, PPV 36.4%.
Limitation / still unknown
Full manuscript Methods, prespecification and locked-model timing not assessed. Low positive predictive value implies confirmatory testing remains relevant; outcome benefit and deployment effectiveness not established.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://eutils.ncbi.nlm.nih.gov/entrez/eutils/efetch.fcgi?db=pubmed&id=43063593&retmode=xml

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 23 Nov 2026. Review scope: Independent reading of original NCBI PubMed XML for the primary JACC article: complete structured Background/Objectives/Methods/Results/Conclusions, electronic publication date and author affiliations. Publisher DOI route was a redirect placeholder; no full manuscript/supplement read..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries. Browse 2026 discoveries.

Related catalog entries

Links use documented relationships where available, plus shared catalog context. A shared topic or model family does not establish a scientific dependency.