AI Science Tracker
EN

Smartphone 3D reconstruction measures eyelid ptosis in a prospective multicenter study

Sun Yat-sen University; State Key Laboratory of Ophthalmology; Zhongshan Ophthalmic Center, Sun Yat-sen University · 1 Nov 2026 · medicine

How tested is it?

Independently or prospectively checked

The level reflects the test the original source reports. This site does not rerun it, and it does not say whether the result is correct.

Discovery

Smartphone 3D reconstruction measures eyelid ptosis in a prospective multicenter study

Source check: Source checked. Not independent scientific confirmation.

Finding: The Digital Rulers of Ptosis system reconstructs the eye region in 3D from a 10-second smartphone video to measure marginal reflex distance 1 (MRD1) and levator function. Across 952 participants (1904 eyes) at 5 hospitals, mean absolute error against specialist measurement was 0.52 mm for MRD1 and 0.95 mm for levator function, with AUC 0.97 for diagnosing ptosis and 0.98 for identifying the surgical approach. Among 206 surgical participants (248 eyes), 3-month recurrence was 7.3%; the authors state that further studies are needed to evaluate clinical impact.

Technology: Neural-network 3D reconstruction and landmark detection from smartphone video

Publication: Peer-reviewed paper · Test context: prospective or independent check. Catalog categories, not an evidence grade.

AI contribution
Neural-network 3D reconstruction and landmark detection from smartphone video yield eyelid measurements and classification.
Test and result
Prospective 5-hospital measurement study against same-day oculoplastic specialist assessment (952 participants), with 3-month postoperative follow-up.
Limitation / still unknown
Clinical impact not evaluated; specialist measurement is the reference standard; recurrence rate is compared with published rates only; abstract and PMC full text reviewed.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1001/jamaophthalmol.2026.4120%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1001/jamaophthalmol.2026.4120

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Author affiliations and publisher full text not accessed. Author affiliations from OpenAlex metadata.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 4/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open in the full catalog for filters, charts and related discoveries. Browse medicine discoveries. Browse 2026 discoveries.

Related catalog entries

Links use documented relationships where available, plus shared catalog context. A shared topic or model family does not establish a scientific dependency.