Deep learning detects diabetic macular edema on fundus images
Source check: Source checked. Not independent scientific confirmation.
Finding: Image-level sensitivity was 0.889, specificity 0.889 and AUC 0.954 on a participant-level validation split, with further validation on IDRiD and new data. External-validation numbers were not in the abstract reviewed.
Technology: Deep learning model trained on EyePACS fundus images (32,049 images from 15,892 patients)
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Deep learning detects diabetic macular edema on fundus images
- Test and result
- Participant-level validation split plus independent IDRiD and new data
- Limitation / still unknown
- External numbers not in abstract read; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1016/j.xops.2025.100722%22&resultType=core&format=json
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract and author affiliations read from Europe PMC metadata for this DOI. Publisher full text not accessed.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.