Source check: Source checked. Not independent scientific confirmation.
Finding: Fecal samples from 299 people in Beijing, Suzhou and Hainan were profiled by ITS2 sequencing. A random forest on 19 fungal markers, chosen from five algorithms, reached an AUC of 0.9350 in the discovery cohort (105 patients with lung adenocarcinoma, 61 controls) and AUCs of 0.9538, 0.9628 and 0.8833 in Beijing, Suzhou and Hainan validation cohorts (15 to 44 patients each). Fungal biodiversity and richness were higher in patients. The study is cross-sectional with small validation cohorts.
Technology: Random forest (best of five supervised algorithms) on 19 gut fungal OTU markers
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- A random forest combined fungal markers to separate patients from healthy controls.
- Test and result
- Three geographically separate validation cohorts (AUC 0.8833 to 0.9628).
- Limitation / still unknown
- Cross-sectional design; small validation cohorts; clinical screening value untested; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1186/s12916-023-03095-z%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1186/s12916-023-03095-z
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Publisher full text not accessed. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.
Source check: Source checked. Not independent scientific confirmation.
Finding: Trans-MUF, a transformer system using fundus images and clinical characteristics, reported an AUC of 0.980 on an internal retrospective set, 0.989 on a prospective dataset and 0.932 on a multicenter, cross-machine, multi-operator dataset for distinguishing diabetic nephropathy from non-diabetic renal disease. Nephrologist accuracy rose by 21% with visualization assistance. Cohort sizes and the reference standard are not in the abstract, and the very narrow confidence intervals suggest image-level analysis; this is a version 1 preprint.
Technology: Transformer-based multimodal deep learning system (Trans-MUF) on fundus images and clinical characteristics
Publication: Preprint · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Distinguishes diabetic nephropathy from non-diabetic renal disease to avoid unnecessary biopsy.
- Test and result
- Internal retrospective set, a prospective dataset and a multicenter cross-machine dataset; classified as retrospective or benchmark because prospective freezing and the reference standard are not documented.
- Limitation / still unknown
- Cohort sizes, biopsy reference, patient-level analysis and clinical benefit; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.21203/rs.3.rs-3445845/v1%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.21203/rs.3.rs-3445845/v1
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Version 1 abstract read from Europe PMC metadata for this DOI; author affiliations not retrieved. Full text not accessed. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.
Source check: Source checked. Not independent scientific confirmation.
Finding: Among 135 503 physical examinees, 20.40% had clinically tentative benign nodules and 0.45% highly suspicious nodules at baseline. An XGBoost model built on 322 surgically confirmed benign and 196 malignant cases and 15 routine clinical variables reached AUC 0.76 and accuracy 0.75, and AUC 0.87 and accuracy 0.80 in an external unit dataset. The study is retrospective.
Technology: XGBoost classifier with grid-search tuning on low-dose CT findings and clinical variables
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Model classifies nodules from clinical variables.
- Test and result
- External unit validation set.
- Limitation / still unknown
- Retrospective; modest internal AUC; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1002/cam4.5886%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1002/cam4.5886
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Author affiliations and publisher full text not accessed. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.
Source check: Source checked. Not independent scientific confirmation.
Finding: A machine learning model was developed on the Huawei Heart Study smart-device photoplethysmography data and optimized in 554 individuals with 469,267 PPG datasets. The primary model's best AUC was 0.94 at 4 hours before AF onset, and the optimized model was prospectively validated in 50 patients with paroxysmal AF against 72-hour Holter monitoring (2,808 AF events), with sensitivity 81.9%, specificity 96.6% and accuracy 88.9% for the 0-4 hour window. The validation cohort is small and the data come from a vendor's devices.
Technology: Machine learning model on photoplethysmography signals from smart devices predicting AF onset
Publication: Peer-reviewed paper · Test context: prospective or independent check. Catalog categories, not an evidence grade.
- AI contribution
- A machine learning model predicted imminent AF episodes from wearable PPG data.
- Test and result
- Prospective validation of the optimized model in 50 patients with paroxysmal AF, against 72-hour Holter ECG.
- Limitation / still unknown
- Performance in larger, less selected populations; benefit of early warning; full text not reviewed.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1016/j.jacasi.2021.09.004%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1016/j.jacasi.2021.09.004
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Publisher full text not accessed; author affiliations not retrieved. Author affiliations from OpenAlex metadata.
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 4/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.