GWAS identifies a functional MSTN variant associated with higher lean mass in humans
Source check: Source checked. Not independent scientific confirmation.
Finding: A genome-wide association meta-analysis of DXA-derived lean mass in about 79,000 people identified 63 loci, including a rare MSTN variant associated with higher leg lean mass. Supervised deep residual convolutional networks imputed missing DXA/MRI image-derived phenotypes from raw images for UK Biobank association analyses; statistical GWAS and researcher-led assays supplied the genetic and functional evidence. The findings are observational, largely from European-ancestry participants, and do not establish clinical benefit from myostatin inhibition.
Technology: Supervised deep residual convolutional neural networks for DXA/MRI image-derived phenotype imputation
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Supervised deep residual convolutional networks imputed missing image-derived phenotypes from raw DXA and MRI images, increasing phenotype availability for the GWAS; the genetic association model and functional assays were separate statistical and experimental analyses.
- Test and result
- Deep residual convolutional networks were trained on labeled DXA/MRI images with an 80/20 train/validation split; imputed phenotypes were used in GWAS. The main association analysis used BOLT-LMM; the paper also reports functional characterization of MSTN p.Ile225Thr.
- Limitation / still unknown
- The paper does not establish causal clinical benefit from myostatin inhibition; imputed phenotypes and observational genetic associations have limitations.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.nature.com/articles/s41467-026-77766-9 · https://api.crossref.org/works/10.1038/s41467-026-77766-9
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.
Review date: 23 Nov 2026. Review scope: Publisher abstract, Results, UK Biobank imaging-processing Methods, Discussion limitations and publication metadata..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 3/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.