Echocardiography-based machine learning algorithm for distinguishing ischemic cardiomyopathy from dilated cardiomyopathy
Source check: Source checked. Not independent scientific confirmation.
Finding / tested result: Four echocardiography-based models distinguish angiography-confirmed ischemic from dilated cardiomyopathy in 399 patients; XGBoost achieved optimal-subset AUC 0.934 and external-center validation AUC 0.804. This is retrospective diagnostic performance with limited external sample (79).
Technology: Random forest, logistic regression, neural network, and XGBoost models
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Random forest, logistic regression, neural network, and XGBoost models
- Limitation / still unknown
- The study reports evaluation in the stated cohort, samples, datasets, or engineering setting; performance and practical benefit beyond that evaluated setting remain unknown.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://link.springer.com/article/10.1186/s12872-023-03520-4 · https://doi.org/10.1186/s12872-023-03520-4
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: linked separately.
Review date: 22 Nov 2026. Review scope: Primary result-bearing material for the stated method, result and evaluation, with bibliographic version information..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.