1 discovery from 2026

Discoveries

AIROGS classifier detects glaucoma in retrospective Rotterdam validation

Source check: Source checked. Not independent scientific confirmation.

Finding: An existing deep-learning fundus-image classifier was evaluated on 19,088 eyes from 9,837 Rotterdam Study participants, including 201 eyes with perimetric glaucoma. Eye-level sensitivity was 70.6% at 95% specificity, with ROC-AUC 0.911. Among 61 true positives with earlier images,33 were flagged before diagnosis. This retrospective evaluation of a prospectively collected cohort does not establish improved patient outcomes; image quality affected false positives. The reported specificity operating point was derived from this cohort’s ROC analysis, rather than a separately locked clinical cutoff.

Technology: AIROGS challenge winning deep-learning fundus-image classifier

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
A learned image classifier supplied glaucoma scores used in external diagnostic evaluation.
Test and result
External existing-cohort diagnostic evaluation; not a prospective test of clinical benefit.
Limitation / still unknown
Clinical benefit and deployment outcomes are unestablished. The reported ROC-derived operating point is cohort-specific; prospective validation remains needed. Direct full-text access was blocked; bounded publisher-indexed Methods and Results were reviewed.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://pubmed.ncbi.nlm.nih.gov/42971439/ · https://www.aaojournal.org/article/S0161-6420(26)00846-8/fulltext

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: linked separately.

Review date: 24 Nov 2026. Review scope: Primary PubMed abstract/date/affiliations and publisher-indexed DL-algorithm-development, Validation dataset, participant ROC-threshold Results and Discussion passages. Direct publisher full-text fetch403; no full-PDF review claimed..

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 3/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.

Open the interactive profile for the timeline, or browse all organizations and model families.