Echocardiography video AI detects heart failure with preserved ejection fraction

Source check: Source checked. Not independent scientific confirmation.

Finding: A 3D convolutional neural network on a single apical 4-chamber echo clip, trained on 2,971 cases and 3,785 controls, had AUC 0.95 in validation. In independent testing (646 cases, 638 controls) sensitivity was 87.8% and specificity 81.9%, with 7.3% nondiagnostic outputs, and it correctly reclassified 73.5% and 73.6% of indeterminate HFA-PEFF and H2FPEF results. Patients classified as HFpEF by AI had higher mortality (HR 1.9).

Technology: 3D convolutional neural network on echocardiographic video clips

Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.

AI contribution
A 3D CNN classified HFpEF from one routine echo clip, with a nondiagnostic category for uncertain cases.
Test and result
Testing used an independent multisite dataset and comparison with HFA-PEFF and H2FPEF scores.
Limitation / still unknown
Case-control labels are retrospective; prospective impact is unknown. Abstract-based; full text not reviewed.
Evidence sources and annotation context

Evidence context (descriptions follow the cited sources; test type is a catalog classification):

Evidence sources: https://www.ebi.ac.uk/europepmc/webservices/rest/search?query=DOI:%2210.1016/j.jacadv.2023.100452%22&resultType=core&format=json · https://api.openalex.org/works/doi:10.1016/j.jacadv.2023.100452

Source checked · editorial details

The source page was checked against this entry. Independent confirmation is not assessed by this label.

Source type: paper. Paper: not linked in this catalog; this does not mean no paper exists.

Review date: 26 Nov 2026. Review scope: Abstract read from Europe PMC metadata for this DOI. Author affiliations could not be retrieved (Europe PMC unreachable, Crossref lists none). Publisher full text not accessed. Author affiliations from OpenAlex metadata.

No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.

Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.