Inverse optimal control infers shared and patient-specific squat objectives after knee replacement
Source check: Source checked. Not independent scientific confirmation.
Finding: Bi-level inverse optimal control inferred individual and shared movement-objective weights from recorded squats in six people after total knee replacement. Center-of-mass height and balance were dominant fitted terms, while balance weights varied across subjects; these are model-dependent inferences rather than direct measurements of neural control. The June 15, 2026 preprint reported within-sample trajectory reconstructions. A November 22 revision added leave-one-subject-out testing within the same six-person dataset, reporting mean RMSE 7.36° and correlation 0.95. Neither version establishes prediction from preoperative data, external-cohort generalization or improved clinical outcomes.
Technology: Bi-level inverse optimal control learning latent movement-objective weights from observed trajectories; OpenSim Moco forward model with PRIMA outer optimization
Publication: Preprint · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Inverse optimal control learns the weights of hypothesized movement objectives from observed human trajectories, enabling patient-specific and shared objective inference and reconstruction of squat kinematics. The fixed mechanical simulator and PRIMA optimization routine alone are not the enabling learned result.
- Test and result
- Version 1 fitted individual and pooled objective weights to existing CAMS-Knee squat recordings from six participants, collected 64–87 months after surgery, and compared reconstructed hip, knee and ankle trajectories with those recordings. Its fitted center-of-mass-height and balance terms were dominant in most cases; balance weights ranged from 0.0950 to 0.4158. The version-2 abstract and author update note report leave-one-subject-out fitting on five subjects and testing on the sixth, repeated across the same cohort, with mean RMSE 7.36°, normalized RMSE 17.75% and Pearson correlation 0.95.
- Limitation / still unknown
- The inferred objective weights depend on the chosen cost terms, mechanical model, local optimization and simplified actuation; they do not directly measure human motor-control objectives. No independent external cohort, prospective prediction from preoperative inputs, improved patient outcome or independent replication is established. Uniform ligament parameters and imperfect movement-timing reproduction remain limitations.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.biorxiv.org/content/early/2026/06/15/2026.06.11.731549.source.xml · https://www.biorxiv.org/content/early/2026/11/22/2026.06.11.731549.source.xml · https://api.biorxiv.org/details/biorxiv/10.64898/2026.06.11.731549/na/json
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: linked separately.
Review date: 23 Nov 2026. Review scope: Independently read the complete primary version-1 article sections on inverse weight estimation, cohort, recovered weights, trajectory validation and limitations, plus version-2 primary abstract and author Summary of Updates. Version-2 full article body was not inspected. Version-specific text distinguishes the original within-sample result from later same-cohort cross-validation; the API repeats updated abstract content under earlier metadata..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.