MicroRNA classifiers show weak separation of sepsis from non-infectious inflammation
Source check: Source checked. Not independent scientific confirmation.
Finding: In 299 public whole-blood samples, learned classifiers evaluated literature-curated microRNAs for sepsis discrimination. The selected miR-150-5p/miR-486-5p pair had ROC-AUC 0.95 against healthy controls and 0.64 against non-infectious inflammation; adding the second marker gave no significant improvement. This is retrospective, cross-validated evidence from one cohort. Healthy controls differed demographically; an interstitial-fluid device was proposed but not built or validated.
Technology: Standardized logistic-regression screening; SVM, multilayer perceptron, random forest and XGBoost evaluation
Publication: Peer-reviewed paper · Test context: retrospective or benchmark. Catalog categories, not an evidence grade.
- AI contribution
- Fixed logistic regression screened literature-curated single miRNAs and pairs under 10-fold cross-validation; further classifier families were compared under 5-fold cross-validation.
- Test and result
- 158 sepsis cases, 82 healthy controls and 59 non-infectious inflammation controls; 263 candidate miRNAs. The paired marker gave nested-CV pooled AUC 0.83 (95% CI 0.78–0.88), with no independent cohort. Against non-infectious controls, no tested panel exceeded 0.64.
- Limitation / still unknown
- Clinical utility, prospective performance and interstitial-fluid transfer are unestablished. Whole-blood cell composition and unmeasured clinical covariates may confound associations; no causal role is established.
Evidence sources and annotation context
Evidence context (descriptions follow the cited sources; test type is a catalog classification):
Evidence sources: https://www.frontiersin.org/journals/systems-biology/articles/10.3389/fsysb.2026.1968124/xml
Source checked · editorial details
The source page was checked against this entry. Independent confirmation is not assessed by this label.
Source type: paper. Paper: linked separately.
Review date: 23 Nov 2026. Review scope: Source-provenanced publisher JATS abstract, exhaustive miRNA screening, classifier comparison and limitations, plus affiliations and publication metadata. The represented result is retrospective host-biomarker discrimination; the proposed device and preliminary bench proof are not treated as clinical or AI validation..
No follow-up recorded; this is not a claim that no follow-up exists. Follow-up review scope and date are not recorded. No source-supported relationships recorded.
Editorial assessment: Impact 2/5 · Validation 2/5 · Novelty 2/5. Impact and novelty are editorial judgments; validation follows the annotated test type where one exists. Not an evidence grade. Scoring criteria.